Found 90 products for "

insertion tube

"
गुणवत्ता मरम्मत के लिए ओलिंपस सीएफ-एच 190एल कोलोनोस्कोप कारखाना

मरम्मत के लिए ओलिंपस सीएफ-एच 190एल कोलोनोस्कोप

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; 6. Soft and hard adjustment wire wear, relatively tight; 7. Rubber leakage. Solution: Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard

गुणवत्ता मरम्मत के लिए Olympus TJF-160VR एंडोस्कोप कारखाना

मरम्मत के लिए Olympus TJF-160VR एंडोस्कोप

Olympus TJF-160VR endoscope for repair ► Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. Solution: Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube,

गुणवत्ता मरम्मत के लिए ओलिंपस CHF-P20Q एंडोस्कोप कारखाना

मरम्मत के लिए ओलिंपस CHF-P20Q एंडोस्कोप

Olympus CHF-P20Q endoscope for repair ► Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber ►Problem & Solutoin Brand Olympus Model CHF-P20Q Fault 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution Replace image

गुणवत्ता मरम्मत के लिए ओलिंपस सीएफ-क्यू160एएल कोलोनोस्कोप कारखाना

मरम्मत के लिए ओलिंपस सीएफ-क्यू160एएल कोलोनोस्कोप

Olympus CF-Q160AL scope for repair ► Brief Description Fault: 1.No image, CCD broken; 2.image broken completely; 3.insert tube aging; 4.biopsy tube abrasion; 5.bending section abrasion; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube,all the fstener part,clamp and rubber. ►Problem & Solutoin Brand Olympus Model CF-Q160AL Fault 1

गुणवत्ता मरम्मत के लिए ओलिंपस एनएफ-जीपी फाइबर नासोफारिन्जियल लैरिन्गोस्कोप कारखाना

मरम्मत के लिए ओलिंपस एनएफ-जीपी फाइबर नासोफारिन्जियल लैरिन्गोस्कोप

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair ► Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion Solution: Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber ►Problem & Solutoin Brand Olympus Model ENF-GP Fault 1. Image with black point and image bundle broken 2. Light

गुणवत्ता मरम्मत के लिए Olympus CF-240AI कोलोनोस्कोप कारखाना

मरम्मत के लिए Olympus CF-240AI कोलोनोस्कोप

Olympus CF-240AI Colonoscope for repair ► Brief Description Fault: Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging. Solution: Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending mesh,spiral tube,light guide tube,bending rubber. ►Problem & Solutoin Brand Olympus Model CF-240AI Fault Image blur,insert tube aging,light guide squashed,light guide broken 50%

गुणवत्ता मरम्मत के लिए Olympus GIF-Q150 गैस्ट्रोस्कोप कारखाना

मरम्मत के लिए Olympus GIF-Q150 गैस्ट्रोस्कोप

Olympus GIF-Q150 Gastroscope for repair ► Brief Description Fault: 1. With image; 2. Light bundlebreak badly; 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage badly; 5. Angle tied, bendingsection, wires and helix tube abrasion; 6. Rubberwithout glue. Solution: Replace light bundle, insert tube, biopsy tube, bending section, wires, helixtube and rubber. (No warranty for CCD) ►Problem & Solutoin Brand Olympus Model GIF-Q150 Fault 1. With image; 2. Light bundlebreak badly; 3

गुणवत्ता चिकित्सा सेवाओं के लिए अंतिम समाधान कारखाना

चिकित्सा सेवाओं के लिए अंतिम समाधान

Product Description: Product Summary: The Medical Device Repair Cases product offered is a comprehensive solution for repairing and maintaining Olympus medical devices. With a warranty of 90 days, customers can have peace of mind knowing that their repaired devices are covered for an extended period. These repaired devices are in good condition, ensuring that they function effectively and reliably. The faults that have been addressed include light bundle broken, insert tube

गुणवत्ता मरम्मत के लिए ओलिंपस सीएफ-2टी160एल कोलोनोस्कोप कारखाना

मरम्मत के लिए ओलिंपस सीएफ-2टी160एल कोलोनोस्कोप

Olympus CF-2T160L Colonoscope for repair ► Brief Description Fault: 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber ►Problem & Solutoin Brand Olympus Model CF-2T160L Fault 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy