गुणवत्ता FLEXIBLE ENDOSCOPE FUJINON EG-590WR लाइट गाइड ट्यूब के भागों कारखाना

FLEXIBLE ENDOSCOPE FUJINON EG-590WR लाइट गाइड ट्यूब के भागों

Fujinon EG-590WR EC-590WL EG-530CT ED-530XT Endoscope Tube Light Guide Main Hose Insertion Brand: Fujinon Model: EG-590WR Compatible with: EG-590WR EC-590WL EG-530CT ED-530XT Series:Light Guide Tube We provide trading and service of Ultrasound unit/Transducer, Dynamic system device/parts, Rigid endoscope parts and Flexible endoscope parts, we also provide trading and service of Surgical Instrument like ureteral renal forceps, electrocoagulation hook, mirror sheath, gravel

गुणवत्ता मरम्मत के लिए FUJINON EG-530N गैस्ट्रोस्कोप कारखाना

मरम्मत के लिए FUJINON EG-530N गैस्ट्रोस्कोप

FUJINON EG-530N gastroscope for repair ► Brief Description Fault: 1.Biopsy tube broken; 2.Angle is not enough; 3.Camera over-heating, there are occasional snowflakes on the image and big risk for CCD; 4.Insert tube aging and wrinkle; 5.Light guide tube aging and wrinkle; 6.Stress boot of light guide tube broken; 7.Light bundle broken; 8.EVE tube aging and wrinkle. Solution: 1: Replace CCD; insert tube; light bundle; biopsy tube; bending mesh; wires; bending section; rubber;

गुणवत्ता मरम्मत के लिए Olympus GIF-H170 गैस्ट्रोस्कोप कारखाना

मरम्मत के लिए Olympus GIF-H170 गैस्ट्रोस्कोप

Olympus GIF-H170 gastroscope for repair ► Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube abrasion. 6. Light guide tube aging and wrinkle. Solution: Replace objective lens, light bundle, small lens, insert tube, biopsy tube, wires, helix tube, light guide tube and rubber.

गुणवत्ता मरम्मत के लिए ओलिंपस GIF-1TQ160 गैस्ट्रोस्कोप कारखाना

मरम्मत के लिए ओलिंपस GIF-1TQ160 गैस्ट्रोस्कोप

Olympus GIF-1TQ160 gastroscope for repair ► Brief Description Fault: 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no water supply tube. 6. No bending section assembly. 7. No digital tip. Solution: Replace CCD, digital tip, light bundle, insert tube,biopsy tube, air&water tube, water supply tube,bending section,wires,helix tube and rubber. ►Problem & Solutoin Brand Olympus Model GIF-1TQ160

गुणवत्ता मरम्मत के लिए OLYMPUS CF-H180AL इलेक्ट्रॉनिक कोलोनोस्कोप कारखाना

मरम्मत के लिए OLYMPUS CF-H180AL इलेक्ट्रॉनिक कोलोनोस्कोप

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed. 5. The light guide tube is slightly wrinkled. Solution: Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire,

गुणवत्ता मरम्मत के लिए Olympus GIF-Q150 गैस्ट्रोस्कोप कारखाना

मरम्मत के लिए Olympus GIF-Q150 गैस्ट्रोस्कोप

Olympus GIF-Q150 gastroscope for repair ► Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber. ►Problem & Solutoin Brand OLYMPUS Model GIF-Q150 Fault 1.with image; 2.one eye of light

गुणवत्ता मरम्मत के लिए ओलिंपस GIF-Q180 गैस्ट्रोस्कोप कारखाना

मरम्मत के लिए ओलिंपस GIF-Q180 गैस्ट्रोस्कोप

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light guide tube aging and wrinkle. 8. Pins for wire holder leakage. Solution: Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins

गुणवत्ता मरम्मत के लिए ओलिंपस GIF-H180J गैस्ट्रोस्कोप कारखाना

मरम्मत के लिए ओलिंपस GIF-H180J गैस्ट्रोस्कोप

Olympus GIF-H180J gastroscope for repair ► Brief Description Fault: 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube and rubber. ►Problem & Solutoin Brand Olympus Model GIF-H180J Fault 1.image

गुणवत्ता मरम्मत के लिए Olympus BF-XP160F ब्रोंकोस्कोप कारखाना

मरम्मत के लिए Olympus BF-XP160F ब्रोंकोस्कोप

Olympus BF-XP160F fiber scope for repair ► Brief Description Fault: 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly; 4. Biopsy tube wear, not smooth; 5. Bending section, steel wire, screw tube wear; Solution: Replace CCD, image beam, beam, insert tube, pliers tube, snake bone, steel wire, spiral tube, rubber. ►Problem & Solutoin Brand Olympus Model BF-XP160F Fault 1. Image degumming,